3 | New Zealand One-Way Interface
This article covers the New Zealand One-Way Terminal Device Setups ( Bepoz Version 4.1.0.0). As the name implies, the New Zealand One-Way terminal only communicates one way. Data is only sent from POS to the terminal. Once the transaction is completed on the terminal - the Operator will need to manually close the transaction from the till.
This article covers the New Zealand One-Way Terminal Device Setups ( Bepoz Version 4.1.0.0).
As the name implies, the New Zealand One-Way terminal only communicates one way. Data is only sent from POS to the terminal. Once the transaction is completed on the terminal - the Operator will need to manually close the transaction from the till.
Prerequisites- To manage Devices & Interfaces in BackOffice, the following Operator Privileges will need to be enabled:
- Operator Maintenance 'General' Tab
- System Setup: "Access Venue, Stores & Tills" Flag
- System Setup: "Maintain Venue, Stores & Tills" Flag
Device Setup
Device Setups TCPIP
Device Type | EFTPOS |
External DLL Name | Eftposanz.Dll |
Class Name | NZ One Way |
Device Options | Use ACK/NAK (Only turn this on if your EFTPOS supports sending ACK/NAK) |
Device Setups RS232
Device Type | EFTPOS |
External DLL Name | Eftposanz.Dll |
Class Name | NZ One Way |
Device Options | Use ACK/NAK (Only turn this on if your EFTPOS supports sending ACK/NAK) |
Communication Settings
Baud Rate | 9600 |
Parity | None |
Data | 8 bits, 1 stop bit |
Parity | None |